- ATEX and IECEx Zone 2 approval
- FM C-US approval for Class I, Division 2
- For applications with high-purity hydrogen or oxygen
- Cleaning standard is based on EIGA Doc 33/18 as regards the absence of particles, oils and fats for heat exchangers with the O2 version
- Materials in contact with media are suitability-tested for high H2 and O2 concentrations
- Heat exchanger leak tests using helium are performed on the H2 series as standard
- Nominal cooling capacity 195 kJ/h (40 °C version) or 175 kJ/h (50 °C version)
- Constant dew point stability ± 0.1 °C
- Adjustable outlet dew point and alarm thresholds
- Cooling block temperature display
When powerful cooling is required, the TC-MIDI X2 sample gas cooler with -H2/-O2 heat exchanger is the ideal solution for reliable cooling of hydrogen (H2) and oxygen (O2) in extractive gas analysis. Green hydrogen produced by electrolysis using renewable energy sources is the key to a sustainable, emission-free future in the energy industry.
The safe, reliable cooling of the sample gas is decisive for gas analytics in the electrolyser (e.g. for LEL monitoring), as a higher moisture content is to be expected with some processes. The moisture in the process gas can damage the sensitive measuring cells in the analyser, so the gas temperature is kept below gas dew point at all times, thus causing the moisture to be emitted. The condensate is discharged via an automatic condensate drain.
As well as material-refining measures to prevent hydrogen- induced component damage, the heat exchangers for the H2 series are subjected to a leak test using helium. For the O2 version, special cleaning processes are used to remove particles, oils and fats from parts coming into contact with media. The contamination limits are based on the internationally used and applicable guideline EIGA Doc 33/18 “Cleaning of Equipment for Oxygen Service”.
Many applications require equipment which can be used in explosive areas. This is where the TC-MIDI X2 series provides solutions for Zone 2 or Class I, Division 2.


Datenblatt Messgaskühler TC-MIDI X2 mit Wärmetauscher -H2/-O2, PDF (416 KB)
Data sheet Sample gas cooler TC-MIDI X2 with -H2/-O2 heat exchanger, PDF (395 KB)
Data sheet Sample gas cooler TC-MIDI X2 with -H2/-O2 heat exchanger, PDF (413 KB)
Ficha de datos Refrigerador de gases de muestreo TC-MIDI X2 con intercambiador de calor -H2/-O2, PDF (415 KB)
Fiche technique Refroidisseur de gaz de mesure TC-MIDI X2 avec échangeur thermique -H2/-O2, PDF (408 KB)
数据表样气冷凝器 带换热器-H2/-O2的TC-MIDI X2, PDF (518 KB)
Технический паспорт Охладитель анализируемого газа TC-MIDI X2 с теплообменником -H2/-O2, PDF (437 KB)
Brief Instructions Peltier Sample Gas Cooler TC-MIDI (+) X2 (multi-lingual), PDF (4 MB)
O2 Declaration Heat Exchanger optimised for use with high-purity oxygen, PDF (860 KB) 