Bühler Technologies GmbH

Sample Gas Probes

Sample Gas Probes

Sample gas probes form a critical point between process and analysis system. They extract sample gas from the process stream and supply it to the analysis system. They should already remove undesirable particulates at the sampling point and avoid cold spots thus preventing false measurements. Our probes are easy to maintain without requiring a lot of tools. Their designs are suitable for critical ambient conditions such as explosive areas and provide weather protection.


Product Range

Select various options to find probes suitable for your application.

1
Application Area
Make your selection here for the region of use and the associated standard areas for equipment details.
2
Application
3
Dust concentration / Filter Type
4
Heating
  • Sample gas probe with integrated particle filter for unheated gas sampling from processes with low dust load.
    Sample Gas Probe GAS 222.10
    Probe with integrated particle filter for unheated gas sampling from processes with low dust load. The filter can be replaced without tools.
    Show details
  • Sample gas probe for unheated gas sampling from processes with high dust load
    Sample Gas Probe GAS 222.11
    Probe for blowback compatible in-situ filter for unheated gas sampling from processes with high dust load, including integrated safety filter. This filter can be replaced without tools.
    Show details
  • [Translate to English:] Gasentnahmesonde für explosionsgefährdete Bereiche Zone 2 sowie mit IECEx-Zulassung. Für rückspülbaren in-situ Filter zur unbeheizten Entnahme des Messgases aus Prozessen mit hoher Staubbeladung
    Sample gas probe GAS 222.11 Ex1
    Sample gas probe for Zone 0, 1 and 2 explosive areas. For blowback compatible in-situ filter for unheated gas sampling from processes with high dust load, including integrated safety filter. This filter can be replaced without tools.
    Show details
  • Sample gas probe for Zone 2 explosive areas, IECEx approval.
    Sample Gas Probe GAS 222.11 Ex2
    Sample gas probe for Zone 2 explosive areas, IECEx approval. For blowback compatible in-situ filter for unheated gas sampling from processes with high dust load, including integrated safety filter. This filter can be replaced without tools.
    Show details
  • Heated probe with integrated particle filter for gas sampling from processes with low dust load.
    Sample Gas Probe GAS 222.15
    Heated probe with integrated particle filter for gas sampling from processes with low dust load. The filter can be replaced without tools. The heater is self-regulating.
    Show details
  • [Translate to English:] Sonde zur Gasentnahme GAS 222.15 mit Zertifizierung nach ANSI und CSA
    Sample Gas Probe GAS 222.15 ANSI/CSA
    Heated probe with integrated particle filter for gas sampling from processes with low dust load. The filter can be replaced without tools. The heater is self-regulating.
    Show details
  • Gas sampling probe with special protection (ip66) for maritime industries and ships.
    Sample Gas Probe GAS 222.15-MA
    Heated probe with integrated particle filter with increased degree of protection (IP66). Particularly suitable for use in high-vibration applications (such as marine) due to special design features.
    Show details
  • Gas-sampling-probe with weather protection- Gas 222.17
    Sample Gas Probe GAS 222.17
    Self-regulating heated sample gas probe with integrated particle filter and weather protection. For processes with low dust load. The filter can be replaced without tools.
    Show details
  • [Translate to English:] Selbstregulierend beheizte Gasentnahmesonde GAS 222.17 für Anwendung in ANSI und CSA Szenarien
    Sample Gas Probe GAS 222.17 ANSI/CSA
    Self-regulating heated sample gas probe with integrated particle filter and weather protection. For processes with low dust load. The filter can be replaced without tools.
    Show details
  • Sample gas probe with weather protection, temperature adjustable heater, and integrated particle filter - Gas 222.20
    Sample Gas Probe GAS 222.20
    Sample gas probe with weather protection, temperature adjustable heater, and integrated particle filter. For applications with low dust load. The filter can be replaced without tools.
    Show details
  • Steam-heated sample gas probe with weather protection and integrated particle filter
    Sample Gas Probe GAS 222.20-DH
    Steam-heated sample gas probe with weather protection and integrated particle filter. For processes with low dust load. The filter can be replaced without tools.
    Show details
  • Sample gas probe GAS 222.20 HT
    Sample Gas Probe GAS 222.20-HT
    Isolated and heated probe with outlet filter, built-in glass bead receptacle and weather hood. For applications with low dust load. The filter can be replaced without tools.
    Show details
  • Sample gas probe GAS 222.20 DENOX
    Sample Gas Probe GAS 222.20 Denox
    Gas sampling probe with outlet filter, integrated glass bead jar and weather protection cover. Optimized for applications with low dust loading. The probe filter can be changed without tools.
    Show details
  • ATEX and IECEX Sample gas probe for explosive areas
    Sample Gas Probe GAS 222.20 Ex1
    Sample gas probe for Zone 1, 2, 21, and 22 explosive areas. With weather protection, temperature self-regulating heater, and integrated particle filter. For applications with low dust load. The filter can be replaced without tools.
    Show details
  • ATEX and IECEX Sample gas probe for explosive areas
    Sample Gas Probe GAS 222.20 Ex2
    Sample gas probe for Zone 2 explosive areas, IECEx approval. With weather protection, self-regulated electronic temperature control, and integrated particle filter. For applications with low dust load. The filter can be replaced without tools.
    Show details
  • [Translate to English:] AMEX zertifizierte Sonde GAS 222.20
    Sample Gas Probe GAS 222.20 AMEX
    Sample gas probe with weather protection, temperature self-regulating heater, and integrated particle filter. For applications with low dust load. The filter can be replaced without tools.
    Show details
  • Sample gas probe Denox-MB
    Heated probe with outlet filter in GfP housing, adjustable up to 280 ° C with Pt100, suitable for dust loads up to 2 g / m³ with integrated glass bead container.
    Show details
  • Sample gas probe with weather protection and in-situ filter with blowback system - Gas 222.21
    Sample Gas Probe GAS 222.21
    Sample gas probe with weather protection and in-situ filter with blowback system. With temperature adjustable heater and integrated safety filter. For applications with high dust load. The safety filter can be replaced without tools.
    Show details
  • Sample gas probe for Zone 1, 2, 21, and 22 explosive areas, with weather protection and in-situ filter with blowback system.
    Sample Gas Probe GAS 222.21 Ex1
    Sample gas probe for Zone 1, 2, 21, and 22 explosive areas, with weather protection and in-situ filter with blowback system. With temperature self-regulating heater and integrated safety filter. For applications with high dust load. The safety filter can be replaced without tools.
    Show details
  • ATEX and IECEx Sample gas probe for Zone 1, 2, 21, and 22 explosive areas, with weather protection and in-situ filter with blowback system.
    Sample Gas Probe GAS 222.21 Ex2
    Sample gas probe for Zone 2 explosive areas, IECEx approval. With weather protection and in-situ filter with blowback system. With temperature self-regulating heater and integrated safety filter. For applications with high dust load. The safety filter can be replaced without tools.
    Show details
  • Probe with blowback compatible in-situ filter for unheated gas sampling from processes with high dust load.
    Sample Gas Probe GAS 222.30
    Probe with blowback compatible in-situ filter for unheated gas sampling from processes with high dust load. Manual blowback control.
    Show details
  • [Translate to English:] ATEX und IECEx Gasentnahmesonde für nicht kondensierbare Gase mit hoher Staubbelastung
    Sample gas probe GAS 222.30 Ex1
    Sample gas probe for Zone 0,1 and 2 explosive areas. Probe with blowback compatible in-situ filter for unheated gas sampling from processes with high dust load. Manual blowback control.
    Show details
  • [Translate to English:] ATEX und IECEx Gasentnahmesonde für nicht kondensierbare Gase mit hoher Staubbelastung
    Sample Gas Probe GAS 222.30 Ex2
    Sample gas probe for Zone 2 explosive areas, IECEx approval. Probe with blowback compatible in-situ filter for unheated gas sampling from processes with high dust load. Manual blowback control.
    Show details
  • Sample gas probe with weather protection with blowback compatible in-situ filter. With temperature adjustable heater.
    Sample Gas Probe GAS 222.31
    Sample gas probe with weather protection with blowback compatible in-situ filter. With temperature adjustable heater. The blowback control can be automated. For applications with high dust load.
    Show details
  • ATEX and IECEx sample gas probe for Zone 1, 2, 21, and 22 explosive areas, with weather protection and in-situ filter with blowback system
    Sample Gas Probe GAS 222.31 Ex1
    Sample gas probe for Zone 1, 2, 21, and 22 explosive areas, with weather protection and in-situ filter with blowback system. With temperature self-regulating heater. The blowback control can be automated. For applications with high dust load.
    Show details
  • [Translate to English:] ATEX und IECEx Sonde zur Gas-Entnahme
    Sample Gas Probe GAS 222.31 Ex2
    Sample gas probe for Zone 2 explosive areas, with IECEx approval, weather protection and in-situ filter with blowback system. With temperature self-regulating heater. The blowback control can be automated. For applications with high dust load.
    Show details
  • Sample gas probe with weather protection and removable in-situ filter with blowback system.
    Sample Gas Probe GAS 222.35
    Sample gas probe with weather protection and removable in-situ filter with blowback system. With temperature adjustable heater. For applications with high dust load not prone to fouling. The in-situ filter can be removed without tools.
    Show details
  • Sample gas probe for Zone 1, 2, 21, and 22 explosive areas, with weather protection and in-situ filter with blowback system.
    Sample Gas Probe GAS 222.35 Ex1
    Sample gas probe for Zone 1, 2, 21, and 22 explosive areas, with weather protection and in-situ filter with blowback system. With temperature self-regulating heater. The blowback control can be automated. For applications with high dust load not prone to fouling. The in-situ filter can be removed without tools.
    Show details
  • Sample gas probe for Zone 2 explosive areas, IECEx approval. With weather protection and in-situ filter with blowback system.
    Sample Gas Probe GAS 222.35 Ex2
    Sample gas probe for Zone 2 explosive areas, IECEx approval. With weather protection and in-situ filter with blowback system. With temperature self-regulating heater. The blowback control can be automated. For applications with high dust load not prone to fouling. The in-situ filter can be removed without tools.
    Show details
  • Sample gas probe with removable in-situ filter for unheated gas sampling from processes with high dust load not prone to fouling.
    Sample Gas Probe GAS 222.35-U
    Sample gas probe with removable in-situ filter for unheated gas sampling from processes with high dust load not prone to fouling. The blowback control can be automated. The in-situ filter can be removed without tools.
    Show details
  • [Translate to English:] Sonde für Messgas nach ANSI/CSA Zertifizierung
    Sample gas probe GAS 222.35-U Ex1
    Sample gas probe with removable in-situ filter for unheated gas sampling from processes with high dust load not prone to fouling. The blowback control can be automated. The in-situ filter can be removed without tools.
    Show details
  • [Translate to English:] Sonde für Messgas nach ANSI/CSA Zertifizierung
    Sample gas probe GAS 222.35-U Ex2
    Sample gas probe with removable in-situ filter for unheated gas sampling from processes with high dust load not prone to fouling. The blowback control can be automated. The in-situ filter can be removed without tools.
    Show details
  • [Translate to English:] Einfache Gasentnahmesonden für gas analyse nach Kundenspezifikationen entwickelt
    Sample Gas Probe APO
    This product group contains customised sample gas probes.
    Show details
Can’t find a suitable product? Click Contact Person to contact one of our experts. Or use the contact form to contact us.
  • Product Archive
    • [Translate to English:]
      Sample Gas Probe GAS 222.20 ATEX
      Sample gas probe for Zone 1, 2, 21, and 22 explosive areas. With weather protection, temperature self-regulating heater, and integrated particle filter. For applications with low dust load. The filter can be replaced without tools.
      Show details
    • [Translate to English:]
      Sample Gas Probe GAS 222.21 ATEX
      Sample gas probe for Zone 1, 2, 21, and 22 explosive areas, with weather protection and in-situ filter with blowback system. With temperature self-regulating heater and integrated safety filter. For applications with high dust load. The safety filter can be replaced without tools.
      Show details
    • [Translate to English:]
      Sample Gas Probe GAS 222.31 ATEX
      Sample gas probe for Zone 1, 2, 21, and 22 explosive areas, with weather protection and in-situ filter with blowback system. With temperature self-regulating heater. The blowback control can be automated. For applications with high dust load.
      Show details
    • [Translate to English:]
      Sample Gas Probe GAS 222.35 ATEX
      Sample gas probe for Zone 1, 2, 21, and 22 explosive areas, with weather protection and in-situ filter with blowback system. With temperature self-regulating heater. The blowback control can be automated. For applications with high dust load not prone to fouling. The in-situ filter can be removed without tools.
      Show details
  • Contact Person

FAQ: Sample Gas Probes

  • What are Sample Gas Probes?

    Sample Gas Probes are critical interfaces between the process and the analysis system. Depending on the application conditions, they can already represent the first stage of the gas conditioning system.

  • What does the selection of a suitable sample gas probe depend on?

    A fundamental criterion for selecting a sample gas probe is the level of solid contamination at the sampling point, such as dust and coarse particles. Depending on the contamination level, the sampling filter is positioned either inside or outside the process stream. It must then be determined whether the sampling point should be heated or unheated. In addition, the environmental conditions at the sampling location must be assessed and, if necessary, appropriate protective measures must be taken into account.

  • Are Bühler Technologies sample gas probes maintenance-friendly?

    Yes, maintenance of the pumps is simple and can be carried out without the use of special tools. The back-purgeable pumps in the product range are maintenance-free over long service intervals.

  • Where can I obtain more information about the sample gas probes?

    Further information about the products can be found in the data sheets. You may also contact one of the listed representatives or arrange an on-site consultation with the responsible sales engineer. Written inquiries can be sent to: analysentechnik@remove-this.buehler-technologies(dot)com.